A High Precision Digital L/C Power Meter Board
THINK IT! MAKE IT! INVENT!
SKU: PROD0631
Features:
ICSH014A is a “Capacitance, Inductance Measuring” module.
Engaged in the development of electronic engineers often need to measure inductance and capacitance, and inductance capacitance meter sold on the market price is higher, and the measurement of small capacitance inductance and small error, this instrument based on LC resonant principle, join the accurate measurement of high-speed micro controller calculation, small capacitance can be measured the inductance 1uH and less than 1pF, the maximum this is also the characteristics of the instrument, particularly suitable for microwave production and switching power supply transformer, inductance measurement.Four measured mode for ICSH014A (LC module) :
1.C mode…… Capacitance (0.01pF-10uF).
2.L mode…… Inductance (0.001uH-100mH).
3.HL mode…… Large inductance (0.001mH-100H)
4.HC mode…… Large capacitance (1uF-100mF)All stalls are automatic range, the use is very convenient. In this way, ICSH014A Whether from the measurement range and measurement precision can completely replace any kind of inductance and capacitance measuring instrument on the market, the performance parameters to the digital bridge, is a highly cost-effective instrument.The Technology Parameters:
https://s3-ap-southeast-1.amazonaws.com/a2.datacaciques.com/00/NDAy/ec56fa3f5894e163/d0fbeb6d0aaf10ef.jpg
https://s3-ap-southeast-1.amazonaws.com/a2.datacaciques.com/00/NDAy/9409d6ddbf4727a4/78539408fe2b168f.jpg
Structure Introduction:
The overall effect diagram . When in use, you can use the Micro USB connection line is connected to the computer USB testing instrument power supply, if the user has a mobile phone charger with USB or with 5V power adapter with DC plug can also be directly to the instrument power supply. Special note: if you are using DC plug adapter, polar please hole positive confirmation, peripheral negative, while the Micro USB interface does not occur polarity error conditions.Instrument structure:
The button has a total of 5, “Reset” to 0 “HC” button, large capacitance, inductance, select “HL” option, “L/C” and black expansion function button. The HC, HL and L/C selection is self lock , a press release was 1, 0, and X represents the arbitrary function, see the table below:
ICSH014A Fuction table
https://s3-ap-southeast-1.amazonaws.com/a2.datacaciques.com/00/NDAy/31bf695426d9c1ea/084ff1b7b4dccf94.jpg
Usage:
1. Connecting computer USB as the tester and switch on the power supply.2. According to the element to be tested for the selection of mode, to choose to measure inductance Lx, capacitance Cx, inductance or capacitance HC HL, in measuring terminal open state from the screen to see:
inductance: Measure Lx 0.000uH
The capacitive display: Measure Cx 0.00pF
Large inductance shows: Measure HL 0.000mH
Large capacitor shows: Measure HL 0.00uF3. Because of the measurement principle of the HC file is different, first stated the following Lx, Cx and HL three mode of operation:
In the three mode , the measurements are required for zero adjustment. The methods according to different inductance, capacitance .
Cx mode in terminal open state, press “Reset” key, the screen shows “Setting… OK “after the release, the screen time line should display” 0.00pF “; HL and Lx mode, the terminal short-circuit condition, press” Reset “key, the screen shows” Setting… OK “after the release, the screen time should show” 0.000mH “and” 0.000uH “, after the open circuit terminal for display” Over Range!”. Then, you can put the inductance connected test instrument to test.
In the measuring result displayed, press the function keys are black, will display the test frequency current.4. In the HC file, please make sure the capacitor is fully discharge to be measured, and then the red test clamp capacitor cathode, black test clamp capacitor anode, read the test results from the display screen and can, need to pay attention to is, the measurement of large capacity (more than 10mF), the test time can be more than 1 seconds, the test time of capacitor the longer the 100mF, about 7-8 seconds before the results.
Matters Attention:
1. HC mode measuring electrolytic capacitor, please note the polarity is negative, red black.
2. If the measurements before the display is 0, sometimes also need to zero adjustment, this might be the deviation is negative, but the display will not show negative.
3. Is strictly prohibited in the test terminal element when pressed zeroing button, this operation will lead to the erroneous results.
4. Is strictly prohibited without testing capacitor discharge, otherwise there may result in damage to the meter.
5. To use the 5V adapter module power supply, ensure that the polarity is negative “”, otherwise it will damage the module.
100% Brand New.
Size: 8cm x 5cm x 2cm (L x W x H)
Model: LC100-A
Supply power:+5v ,mini USB interface
Measurement accuracy: 1%
Capacitance measuring range: 0.01 pF – 10uF (The minimum resolution: 0.01 pF )
Inductance measuring range: 0.001 uH – 100mH
Big inductance measuring range: 0.001 mH – 100H (The minimum resolution: 0.001uH )
Test frequency range: L/C about 500KHZ/Big inductance 500HZ
Effective display digits: 4 digits
LCD display mode: 1602
Note: When measuring the frequency of the inductance or Capacitance, please press the black button,
as the PIC shows.
Please reset to zero, before testing a Capacitance or inductance, or it may damage the board.
If the result on the LCD is not stable,it s normal due to the poor quality of L/C.
Package Includes:
1 x High Precision L/C Meter Board LC100-A
Contact us:
T (+63) 02 577 8214
M (GLOBE) (+63) 995 629 48 43
M (SMART) (+63) 949 966 59 73
Email: [email protected]
Facebook: EDW ElecDesignWorks
Website: www.elecdesignworks.com
Address: 2nd flr. CW Arcade Bldg., #20 Alcalde Jose St. Brgy Kapasigan Pasig City, Philippines 1600
This seller has been a member since: May. 28, 2015
Member Location:
Total Classifieds: 650
Why seller feedback is important?
Transact with most credible & reputable sellers
Know the seller you are going to deal with
Claim warranty long after purchasing the item
Warn you and other buyers against scams
Motivates sellers to provide good service